Section 5 − operation, Controls, 1. controls – Miller Electric pmn User Manual

Page 20

Advertising
background image

OM-228 305 Page 16

SECTION 5 − OPERATION

5-1.

Controls

1

4

2

3

ON

OFF

PRESSURE

60 PSI

5

6

24

27

20

16

24

27

20

16

1

24

27

20

16

Requires

90-120 PSI

(621-827 kPa)

Supply

Setting Gas/Air Pressure

1

Output Control

Use control to set cutting output.

Place control in Gas/Air Set position to safely
adjust gas/air pressure. Only gas/air circuit
is activated.

If 22-27 amperes of cutting output is used
with 115 VAC input power, and the overload
protection on the input power circuit fre-
quently opens, either reduce the cutting out-

put and/or the cut time or find more adequate
power (see Section 4-1).

2

Trouble Lights (See Section 6-2)

3

Power Light

4

Power Switch

Setting Gas/Air Pressure

5

Air Filter/Regulator

6

Pressure Adjustment Knob

Place Output control in Gas/Air position and
turn on gas/air supply. Lift knob and turn to
adjust pressure. Push knob down to lock in
setting.

Place Output control in desired cutting
output.

.

At ambient temperatures below −5

5

C

(23

5

F), readjustment of gas/air

pressure regulator may be necessary.

Ref. 227 835-A / Ref. 804 486-A

5

6

Set To

60 PSI (414 kPa)

Advertising