5. foot alignment – Miller Electric 625 User Manual

Page 21

Advertising
background image

OM-216 244 Page 17

1

Leg Screw

2

Foot

3

Ferrule

4

Ferrule Grip

5

Stud

.

Alignment of the foot is very important,
if the foot is not aligned properly it can

create bad welds in the form of hang−

ups.

Place a stud into the chuck and a ferrule into

the ferrule grip. The stud should sit perfectly

in the center of the ferrule. If not, loosen the

flat head screws on the legs holding the foot.
Position the foot so the stud is perfectly

aligned in the ferrule. Retighten the flat head

screws.

5-5. Foot Alignment

1

5

2

3

4

5-6. Connecting Stud Gun and Work Clamp to Power Source

1

2

3

4

Perform the following procedures when

connecting stud gun to power source:

Connect weld cable

Connect control cable

.

Use the same instructions provided if
connecting to an extension cable.

Connecting Weld Cable and Work

Ground Cable
1

Flat

2

Keyway

To connect to receptacle, align keyway, in-

sert connector, and turn clockwise (approx-

imately 1/2 turn).
Connect stud gun to black output terminal

labeled gun.
Connect work cable to black output terminal

labeled work.
Connecting Control Cable
3

Key

4

Keyway

Align key in end of control cable with key

way inside connector on front of power sup-

ply. Push the connectors together. Turn re-

taining nut on control cable clockwise.

When nut is snug the connection is com-

plete.
To remove, unscrew connector counter

clockwise.

Ref 802 385-A

Advertising