OM-216 244 Page 22

6-2. Time/Amperage Control

1

Time/Amperage Select Button

Depress button to select Time/Amperage

control.
2

Time Meter

3

Amperage Meter

4

Time/Amp Adjustment Control

Rotate knob clockwise to increase time/am-

perage

S Time - (5-1000 milliseconds)

S Amperage - (50-1000 amps)

Rotate knob counterclockwise to decrease

time/amperage.

.

The active display will be lit and adjust-
able. The inactive display will turn off.

TIME/AMP ADJUSTMENT

SELECT

TIME (ms)

AMPERAGE

4

3

1

2

Ref. 232 187-A