NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNING

Do not place loose insulation or

any other material in the space

around the fireplace or the

chimney. Insulation placed on

or around the fireplace or chim-

ney may cause adjacent wood to

overheat and catch on fire.

WARNING

The top of the fireplace is not

zero clearance. Do not place

any insulating material in the

space above the fireplace for a

height of 7 feet from the base of

the fireplace.

7

1. The fireplace must be installed against a

finished wall (like drywall finish). It must

not be installed against a vapor barrier or

exposed insulation (see Figure 5).

2. Combustible materials like wood, plywood,

particle board or drywall can be in direct

contact with the fireplace standoffs. Two

inch (50mm) clearance to combustibles

must be kept around the chimney.

3. Do not block the fireplace’s hot air vents or

air inlets as this will cause the fireplace to

overheat.

ENCLOSURE

Figure 5

NOTE: Chase wall and floor must be insulated

in the same manner than the rest of the building

below the attic.

CEILING/FLOOR

SEPARATION

MUST HAVE THE SAME INSULATION

LOCAL CODE REGULATION FOR CEILING

MUST BE APPLIED TO THE CEILING/FLOOR

SEPARATION, I.E. FIRESTOP, ETC.

MUST HAVE THE SAME FIRE RATING

AS ADJACENT CEILING.

AS ADJACENT CEILING.

ROOF SUPPORT

ATTIC

FIRESTOP

FLASHING

NON COMBUSTIBLE

CHASE TOP

FIREPLACE

2"

7 ft. Min.

FINISHED

WALL

WARNING

The header should rest on top

of the metal spacers. Do not

alter the spacers or notch the

header to fit around them. Do

not block the air inlet or outlet

as this will cause the fireplace

to overheat.