Philips Magnavox ELITE ME43BKSP User Manual

Page 9

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

9

Figure 8

OUTSIDE

INTAKE

ALUMINIUM TAPE

PLASTIC

COVER

FLEXIBLE PIPE

SCREW

OPENING

FACING DOWN

WALL

OUTSIDE AIR CONNECTION

TO THE FIREPLACE

FIREPLACE

CONNECTION

ALUMINIUM

TAPE

INSULATION

FLEXIBLE

PIPE

FIREPLACE

PLASTIC COVER

LOOP IS MANDATORY

7' MAX.

OUTSIDE AIR CONNECTION

(Detail A)

(Detail B)

(Detail C)

Outside Air Installation

The outside air assembly must be installed

according to the following guidelines:

1. The maximum length of 4" I.D. (100 mm)

insulated flexible duct is 20 feet (6.1 m). If a

longer duct is required, use a 6" I.D. (150mm)

insulated flexible duct. The maximum length

is 40 feet (12 m). Refer to Figures 8B and

8C for connections.

2. The duct and register may be installed above

or below floor level.

3. The outside air register must not be installed

more than 7 feet (2.1 m) above the base of

the fireplace.

4. The outside air assembly must draw air from

outside the house. It must not draw air from

the attic, the basement or a garage.

5. Locate the outside register where it will be

well away from automobile exhaust fumes

or other vents.

6. The outside air register should be installed

where it is not likely to be blocked by snow

or exposed to extreme wind.

7. It is recommended to install the outside air

register at floor level. However, if you must

raise the air register above the fireplace level,

you will have to make a loop to the floor with

the flexible pipe to prevent from causing a

draft in the outside air register (see Figure

8 Detail A).

INSTALLATION OF THE BLOWER KIT

MODEL UZY3

Note: This blower kit can easily be installed when

the fireplace has a pre-installed junction box.

You just have to plug them in.

Rating: 120 Volts, 60Hz, .63A.

The blowers have magnetic blower mounts.

The junction box (factory installed on approved

fireplaces for the use of this blower kit) must be

connected to 110 VAC service before perma-

nently enclosing the fireplace. The access hole

for connecting the 110 VAC is located on the

lower right exterior side of the fireplace.

Installation instructions:

1. Open the bottom louver of the fireplace.

2. Place each blower kit into the fireplace

side opening 1" from the back of the

fireplace.

3. Install the automatic blower activator on

the side of the firebox (the blower activator

has a magnetic mount).

4. Plug the blower kit into the junction box.

5. Ground both blowers to the back panel

using the green screws (see Figure 9).

Figure 9

ELECTRICAL CONNECTION

WITH

GROUND CONNECTION

THERMODISC, AUTOMATIC

THERMAL FAN ACTIVATOR

CONNECTOR FOR

OPTIONAL RHEOSTAT

FAN WITH

MAGNET

FAN WITH

MAGNET

NOTE: The fireplace must be electrically connected and grounded in accordance with local codes

or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For U.S.A.

installations, follow local codes and the National Electrical Code ANSI/NFPA No 70.

CAUTION: SHOULD THIS BLOWER REqUIRE SERVICING, THE POWER SUPPLY MUST BE

DISCONNECTED.

These blowers require periodic maintenance. Check the area in front of the blowers and wipe or

vacuum at least once a month during the burn season.

Advertising