UPS signals (CN7)

The PV-1800 has signals that, combined with external circuitry, can be used to implement a UPS

function. There is an input for turning off the 20W power supply (SWITCHER_OFF), two status

inputs (UPS_STATUS1 and UPS_STATUS2), and an output (UPS_PWROFF) that can tell the

external circuitry to turn off power after a programmable delay.

Connector layout:

* = do not connect, for internal factory use.

PV-1800 register interface

The PV-1800 has three blocks of I/O ports: the modem UART, the external RS232

UART and the internal registers. The UARTs are 16C550 compatible and use

eight I/O ports each.

The base addresses of the modem UART and external RS232 UART are configured

on configuration jumper 1,2,3 and 4,5,6 respectively, see the table printed

on the board. The IRQ of both UARTs are configured on the IRQ jumpers. You

cannot use the same IRQ for both UARTs.

Base address
Configuration jumper 7, 8 configure the base address of the sixteen internal

registers. This table is also printed on the board.

ST1

Base address

7 8 Registers
0 0 200h

0 1 220h

1 0 300h
1 1 320h

Pin no Name

1

GND

2

*

3

*

4

*

5

*

6

UPS_PWROFF

7

+5V

8

UPS_STATUS2

9

UPS_STATUS1

10

SWITCHER_OFF

.

%-

%-# '

$