6-3. Voltmeter/Ammeter Help Displays

.

All directions are in reference to the front of the unit.
All circuitry referred to is located inside the unit.

1

Help 0 Display

Indicates a shorted thermistor in the transformer of the

unit. If this display is shown, contact a Factory Autho-

rized Service Agent.
2

Help 2 Display

Indicates a malfunction in the thermal protection circuitry

located on the transformer of the unit. If this display is

shown, contact a Factory Authorized Service Agent.
3

Help 3 Display

Indicates the transformer of the unit has overheated. The

unit has shut down to allow the fan to cool it (see Section

4-2). Operation will continue when the unit has cooled.
4

Help 4 Display

Indicates a malfunction in the thermal protection circuitry

located on the secondary heat sink of the unit. If this dis-

play is shown, contact a Factory Authorized Service

Agent.
5

Help 5 Display

Indicates the secondary heat sink of the unit has over-

heated. The unit has shut down to allow the fan to cool

it (see Section 4-2). Operation will continue when the unit

has cooled.
6

Help 6 Display

This is a two-stage error. The warning stage occurs

when the primary voltage drops more than 12% below

the linked primary voltage setting for more than 30 sec-

onds. The display flashes a HELP 6 message during

idle, but the welder continues to operate normally. Once

the primary voltage returns to less than 10% below the

linked primary voltage setting the flashing error ceases.

The shutdown stage occurs when the primary voltage

drops more than 20% below the linked primary voltage

setting for more than 30 seconds. A constant HELP 6

message is displayed, and weld output is disabled. Once

the primary voltage returns to less than 10% below the

linked primary voltage setting, the constant error mes-

sage ceases, and weld output is enabled.
NOTE: Operating the welder out of the normal operating

range (

±

12% of the linked primary) will affect the output

and reliability of the welder, and is not recommended.
7

Help 7 Display

This is a two-stage error. The warning stage occurs

when the primary voltage rises more than 12% above the

linked primary voltage setting for more than 30 seconds.

The display flashes a HELP 7 message during idle, but

the welder continues to operate normally. Once the pri-

mary voltage returns to less than 10% above the linked

primary voltage setting the flashing error ceases.

The shutdown stage occurs when the primary voltage

rises more than 20% above the linked primary voltage

setting for more than 30 seconds. A constant HELP 7

message is displayed, and weld output is disabled.

Once the primary voltage returns to less than 10% above

the linked primary voltage setting the constant error

message ceases, and weld output is enabled.
NOTE: Operating the welder out of the normal operating

range (

±

12% of the linked primary) will affect the output

and reliability of the welder, and is not recommended.
8

Help 9 Display

Indicates a shorted thermistor on the secondary heat

sink of the unit. If this display is shown, contact a Factory

Authorized Service Agent.

2

A

V

3

A

V

HE.L P−2

HE.L P−3

4

A

V

HE.L P−4

5

A

V

HE.L P−5

6

A

V

HE.L P−6

7

A

V

HE.L P−7

A

V

HE.L P−0

A

V

HE.L P−9

8

1

Advertising
This manual is related to the following products: