OM-203 034 Page 20

4-12. Connecting Input Power

ssb2.4* 1/94 − 801 523-B / 801 946

Tools Needed:

5/16 in

Input Filter

Board

L1

=GND/PE

!

Turn Off welding power source, and

check voltage on input capacitors

according to Section 6-3 before pro-

ceeding.

Check input voltage available at site.
Remove left side panel.

1

Input And Grounding Conductors

See Section 4-11.
Install ring terminals of proper size onto input

conductors for connection to input filter board

terminals (see illustration).
2

Line Disconnect Device

Select type and size of overcurrent protection
using Section 4-11. Connect input and
grounding conductors to a deenergized line
disconnect device.

Reinstall left side panel.

L1

2

L2
L3

1

L2

L3

!

Always connect

grounding conductor

first.