OM-203 034 Page 22

5-3. Meter Functions For CV Only Models

.

The meters display the actual weld output values for approximately three seconds after the arc is broken.

Mode

Meter Reading At Idle

Meter Reading While Welding

MIG

Preset Volts

Blank

V

A

24.5

Actual Volts

Actual Amps

V

A

24.5

250

Pulsed

MIG

Pulse Display

Pulse Display

V

A

PPP

PPP

Actual Volts

Actual Amps

V

A

24.5

250

5-4. Front Panel Controls For CC/CV Models

1

Power Switch

.

The fan motor is thermostatically
controlled and only runs when cooling is

needed.

2

Voltmeter (see Section 5-5)

3

Ammeter (see Section 5-5)

4

V/A (Voltage/Amperage) Adjust Control

5

Voltage/Amperage Control Switch

For front panel control, place switch in Panel

position and use the V/A Adjust control.
For remote control, make connections to Re-

mote 14 receptacle, and place switch in Re-

mote position. In most modes, remote control

is a percent of the V/A Adjust control setting.

Value selected on V/A Adjust is maximum

available on remote. In the MIG mode, re-

mote control provides full range of unit output

regardless of V/A Adjust control setting.
6

Mode Switch

The Mode switch setting determines both the

process and output On/Off control (see Sec-

tion 5-6). Source of control (panel or remote)

for the amount of output is selected on the V/A

Control switch.
For Air Carbon Arc (CAC-A) cutting and

gouging, place switch in the Stick position.

For best results, place Inductance/Dig con-

trol in the maximum position.
7

Inductance/Dig Control

Control adjusts Dig when the Stick or CC

mode is selected on the Mode switch. When

set towards minimum, short-circuit amper-

age at low arc voltage is the same as normal

welding amperage.
When set towards maximum, short-circuit

amperage is increased at low arc voltage to

assist with arc starts as well as reduce stick-

ing while welding (see volt-ampere curves in

Section 4-3).
Select setting best suited for application.
Control adjusts inductance when MIG posi-

tion is selected on the Mode switch. Induc-

tance determines the “wetness” of the weld

puddle. When set towards maximum, “wet-

ness” (puddle fluidity) increases.
When Pulsed MIG, or one of the TIG modes

is selected, this control is not functional.

2

3

4

7

196 445

1

5

6