Electrical

Parameter

Value

Comment

Operating Voltage

9 to 16 Volts

DC Voltage

Power Consumption

<100mA

Average Current Drain

Load Equivalence Number (LEN)

2

NMEA 2000

®

Spec. (1LEN = 50 mA)

Reverse Battery Protection

Yes

Indefinitely

Load Dump Protection

Yes

Energy Rated per SAE J1113


Mechanical

Parameter

Value

Comment

Size

4” Diameter x 1.65” Tall Not Including Antenna Mount Base

Weight

6 oz.

Not Including Antenna Mount Base

Mounting

Deck or Pole

Environmental

Parameter

Value

IEC 60954 Classification

Exposed

Degree of Protection

IP67

Operating Temperature

-25°C to 55°C

Storage Temperature

-40°C to 70°C

Relative Humidity

93%RH @40° per IEC60945-8.2

Vibration

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7

Rain and Spray

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8

Solar Radiation

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

Corrosion (Salt Mist)

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Electromagnet Emission

Conducted and Radiated Emission per IEC 60945-9

Electromagnetic Immunity

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Safety Precautions

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12


7 Technical Support

If you require technical support for Maretron products, you can reach us in one of the following
ways:

Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

[email protected]

World Wide Web:

http://www.maretron.com

Mail:

Maretron,

LLC

Attn: Technical Support

9014 N. 23

rd

Ave Suite 10

Phoenix, AZ 85021 USA

Advertising