11: Software Code (16 bits) – set this field’s value to 0x0001, which is the identifier for

this version of the Maretron proprietary protocol

12: Maretron Command (8 bits) – set this field’s value to 0x30, which will force the GPS

Engine to restart as selected by the following field.

13: Restart mode (8 bits) – set this field’s value to select the restart mode, 0=Factory

restart, 1=Cold start.


PGN 126208 – NMEA Request Group Function – Transmission Periodic Rate
This PGN will enable or disable the periodic transmission of specific PGNs.

Field 1: Complex Command Group Function Code (8 bits) – set this field’s value to 0x00,

which denotes a request PGN

2: Requested PGN (24 bits) – set this field’s value to the corresponding PGN for which

you wish to change the periodic rate.

3: Transmission Interval (32 bits) – set this field’s value to 0x0 to disable the periodic

transmission of the PGN identified in field 2 above. Set this field’s value to
0xFFFFFFFE to restore periodic transmission of the PGN identified in field 2 at the
default rate. Otherwise, program in the desired periodic rate to restore periodic
transmission of the PGN identified in field 2 above at the desired rate. The resolution
of this field is 1 millisecond.

4: Transmission Interval Offset (16 bits) – set this field’s value to 0xFFFF; all other

values will cause the request to be rejected.

5: Number of Pairs of Commanded Parameters to Follow (8 bits) – set this field’s value

to 0x0.