5.5.7 Stop State

When motor stop is required, the PWM signals are disabled and the
power switches are switched off. The state diagram for this state is
shown in

Figure 5-12

.

Figure 5-12. STOP State

5.5.8 Fault State

If over-voltage, over-current, or commutation fault occurs, the motor
control PWM’s are disabled and control enters the fault state, where it
remains until RESET or clear failure (start switch set OFF or
PCMode&ClearFail). The fault state is indicated by the Red LED diode
blinking.