Miller Electric XMC 4000 User Manual

Page 36

Advertising
background image

OM-221 694 Page 32

SC-187 212-A

.

All directions are in reference to the front
of the unit. All circuitry referred to is

located inside the unit.

Help 0

Indicates shorted thermistor RT2 on left side

of unit. Contact a Factory Authorized Ser-

vice Agent.

Help 1

Indicates a malfunction in the primary power

circuit. Contact a Factory Authorized Ser-

vice Agent.

Help 2

Indicates a malfunction in the thermal

protection circuitry on left side of unit. Con-

tact a Factory Authorized Service Agent.

Help 3

Indicates overheating on left side of unit. Unit

will shutdown and fan will run until internal

temperature drops within operational range.

Help 4
Indicates a malfunction in the thermal

protection circuitry on right side of unit. Con-

tact a Factory Authorized Service Agent.
Help 5
Indicates overheating on right side of unit.

Unit will shutdown and fan will run until inter-

nal temperature drops within operational

range.
Help 6
Indicates input voltage is too low and unit has

automatically shut down. Operation will con-

tinue when voltage is within an acceptable

lower range limit (15% below acceptable in-

put voltage). Contact an electrician to check

input line voltage.
Help 7
Indicates input voltage is too high and unit

has automatically shut down. Operation will

continue when voltage is within an accept-

able upper range limit (15% above accept-

able input voltage). Contact an electrician to

check input line voltage. HELP 7 may also in-

dicate a bus voltage imbalance.

Help 8

Indicates a malfunction in the secondary

power circuit of the unit. Contact a Factory

Authorized Service Agent.

Help 9

Indicates a shorted thermistor RT1 on right

side of unit. Contact a Factory Authorized

Service Agent.

Help 15

Indicates a malfunctioning cooling unit. Unit

will shut down immediately. Turn off primary

power. Check and repair cooling unit compo-

nents as necessary. Unit will operate when

power to unit is turned off and back on.

Help 50

Indicates an overload at the power module.

Reduce weld parameter settings and/or duty

cycle. If error continues, contact a Factory

Authorized Service Agent.

Advertising