The bobcat generator power advantage, Mounting specifications, Accu-rated – Miller Electric Engine-Driven Welder/AC Generator User Manual

Page 3: Not inflated generator power, Smooth power – not spike power, Fuel consumption data

Advertising
background image

To select a generator that has enough power output in watts, add the watts
for the items you want to simultaneously run. Tools and appliances with
induction motors may require 3 – 7 times the listed wattage when starting.
All data listed is approximate — check your tool/appliance for specific
wattage requirements.

Bobcat 3 Phase will easily start and run the following equipment:

TYPICAL EQUIPMENT POWER USAGE

Equipment

Pivot Irrigation (9–1 HP), 9 Tower

Pivot Irrigation (6-3/4 HP, 3–1-3/4 HP, 1–1 HP),

8 Tower with Corner Arm

Starting Watts

Running Watts

Barn Cleaner (5 HP)

11,600

3000

Silo Unloader (5 HP)

12,200

4300

Portable Conveyor (1/2 HP)

3400

1000

Milker (5 HP)

10,500

2800

Hand Drill (1/2 inch)

600

600

Circular Saw (8-1/4 inch)

1400

1400

Air Compressor (1-1/2 HP)

8200

2200

Flood Lights (Vapor)

1250

1000

Refrigerator/Freezer

2200

700

Sump Pump

1300

800

Millermatic

®

212 MIG Welder

6500

6500

(30 – 210, 230 V)

Spectrum

®

625

6900

6900

(30 A, 230 V, 1/2 in cut)

The Bobcat Generator Power Advantage

Tools and motors are designed to operate within 10% of
120/240/480 VAC. The Bobcat’s power generator provides strong
power while keeping the voltage within 10% of 120/240/480 VAC.
This increases tool/motor performance and life.

Accu-Rated

– Not Inflated Generator Power

Miller’s Accu-Rated

11,000 watts of

usable peak power is delivered for a

minimum of 30 seconds. Accu-Rated means peak power is usable for
maximum generator loads such as plasma cutting, Millermatics and motor
starting. Accu-Rated peak power beats the competition’s very short-duration
peak or surge power. Use your peak power, it’s more than a number.

Smooth Power – Not Spike Power

Revolutionary ten-degree skewed-rotor design
optimizes generator performance for smoother
power—not spiked power found with other
brands. Better power — better performance.

Fuel Consumption Data

12-gallon fuel capacity.

On a typical job using 1/8-in 7018 electrodes (125 amps, 20% duty cycle)
expect about 20 hours of operation.

Welding at 150 amps at 40% duty cycle uses approxi mately 3/4 gallon
per hour— about 16 hours of operation.

Under a continuous load of 4000 watts of generator power, the Bobcat
would run for about 14 hours.

IDLE 2200 RPM

3750 RPM

1-Phase
Generator
Power

DC WELD/
3-Phase
Generator
Power

FUEL CONSUMPTION

(Kohler 23 HP Command OHV)

2.00

1.75

1.50

1.25

1.00

0.75

0.50

0.25

0

U.S. GAL/HR

0

25

50

75

100

125

150

175

200

225

250

WELD AMPS AT 100% DUTY CYCLE

0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0 10.0

POWER KVA AT 100% DUTY CYCLE

Waveform Comparison

Bobcat

Competitor

3

A. 20 in (508 mm)
B. 16-1/2 in (419 mm)
C. 1-3/4 in (44 mm)
D. 6-1/16 in (154 mm)
E. 32-3/4 in (832 mm)
F. 45-3/8 in (1153 mm) (Gas)
G. 13/32 in (10 mm) diameter

Height: 33-1/2 in (851 mm)

(to top of exhaust)

Width: 20 in (508 mm)
Depth: 45-7/8 in (1164 mm)

4 Holes

Engine End

G

A

B

C

D

E

F

Mounting Specifications

Advertising