Marmitek MS9770 User Manual

Page 15

Advertising
background image

15

MS9470/MS9770/MS9970

5. PROGRAMMING
THE SC2800 BASE STATION

5.1 REGISTRATION OF RADIO SENSORS

Every sensor must be installed or registered with the base station. In this way, the base station recognises only its own
sensors. Up to 16 sensors can be registered on the SC2800. One of those 16 can be a wired sensor connected to the input
jack at the back of the base station. Each sensor registered by the base station occupies one zone. You can choose to
register the sensors automatically on the next available unoccupied zone, but you can also allocate a sensor to a specific
zone. (refer to B).

A. REGISTER SENSORS ON THE NEXT AVAILABLE FREE ZONE (STANDARD)
Every time you press a key you hear a short confirmation beep.

Set mode switch to INSTALL: All indicators of earlier registered zones come on

Press the TEST button of sensor 1: Indicator of next available free zone comes on

Press the TEST button of sensor 2: Indicator of next available free zone comes on

REPEAT THIS PROCESS UP TO A MAXIMUM OF 16 SENSORS. THE ZONES ARE GOING TO BE OCCUPIED
ONE BY ONE.

Reset the mode switch to RUN 1 or RUN 2: Zone indicators go out.

B. REGISTER SENSORS ON A PRE-DEFINED FREE ZONE (SPECIAL)
Every time you press a key you hear a short confirmation beep.

1. Set mode switch to INSTALL: All indicators of occupied zones come on

2. Key in the required zone (e.g. 14: key 1 + 4)

3. Press the ENTER key on the base station:

4. Press the TEST button of the sensor. The selected zone will now be occupied: Indicator of selected zone comes on

5. Reset the mode switch to RUN 1 or RUN 2: Zone indicators go out.

N.B.: In case that some zone-indicators are on already before you started the registration of sensors, it may be that some
sensors have registered themselves onto the base station. The may be the case because e.g. the MS10 Motion Detector has
detected a motion or a door or window has been opened. You can erase these zones by using the method described in 5.9
(de-registering a zone) or 5.10 (erasing all of all settings).