Setting the OS77 Series

The OS77 Series module must be fully installed and properly wired before
attempting any of adjustment steps. These adjustment steps must be per-
formed before the fine tuning can be accomplished and should be performed
for first time setup of the OS77.

Note for relay output models only (OS77R): The following instructions
assume terminal 5 is grounded. Relay contacts are between terminals 2& 5.

1

. Turn the “SPEED ADJ. ” potentiometer

fully clockwise (Detail 1).

2

. Remove the wire from terminal #2 of

the OS77 terminal block (Detail 2).

3

. Start engine and run at the highest

RPM desired. This is the RPM at
which the engine should be shut-
down if exceeded.

4

. Connect a Voltmeter or a test light

between terminals #1 (positive+) and
terminal #2 (negative) of the OS77 ter-
minal block. You should read no voltage
or the test lamp will be OFF.

5

. Slowly turn the “SPEED ADJ. ”

pot counter-clockwise and stop
the INSTANT the battery volt-
age is indicated on the meter
or the test light comes ON.

6

. Slowly turn “SPEED ADJ.”

pot clockwise about 1/8 of an
inch. Now, tighten the locknut
(bigger nut) on the SPEED
ADJ. pot without disturbing
the setting.

7

. Re-connect the wire to terminal

#2 on the OS77 terminal block.
This reconnects the SPEED
shutdown circuitry.

NOTE: If further adjustment (fine tuning) is needed: Turning the SPEED
ADJ. pot clockwise, RAISES the shutdown point. This allows the engine to
run at a HIGHER RPM. Turning the SPEED ADJ. counter-clockwise LOW-
ERS the shutdown point. This will shutdown the engine at a LOWER RPM.

Warranty

A two year limited warranty on materials and workmanship is
provided with this Murphy product. Details are available on
request and are packed with each unit.

HOOK UP AND ADJUSTMENTS

1 2 3 4

5

OS77

+

+

B

Battery

To Starter

To

Starter

Key Switch

Pressure

Temp.

Rack Puller

Hold coil

Fuel Valve

Ignition Coil

Pickup

518PH/518APH

I

S

1 2 3 4

OS77

+

Battery

Pickup

169PH Magnetic Switch

1 2 3 4

OS77

+

To Starter

Rack Puller

Hold coil

Fuel Valve

Ignition Coil

To Distributor

Ignition

R

G

NO

NC SW1 SW2

B

+

B

Battery

To

Starter

Key Switch

Pressure

Temp.

518PH/518APH

I

S

R

G

NO

NC SW1 SW2

B

S

B

G

C

*

Applies to 518APH model.

***

Applies to Relay output models only. B+ can be

switched on Relay output models if desired.

**

Always use shielded cable.

**

*

**

*

5

5

***

***

***

OS77 Module

Front View

Speed Adj.

Potentiometer

Raise

Lower

Detail 1

OS77D Model Typical Wiring Diagram

(Negative Ground Only)

OS77I Typical Wiring Diagram

(Distributor Ignition Applications)

OS77I Typical Wiring Diagram

(For Shutting Down Magneto Ignitions)

Wiring the OS77 Series

Detail 2

WARNING:

BEFORE WIRING THE OS77 MAKE SURE THE

POWER SOURCE IS OFF AND EQUIPMENT IS STOPPED.

To Pickup

To Battery–

To Battery +

Light

Meter

OR

+

--

1 2 3 4

OS77 Module

Back View

Printed in U.S.A.

®

FRANK W.

MFR.

FRANK W. MURPHY SOUTHERN DIVISION

P.O. Box 1819; Rosenberg, Texas 77471; USA
tel. (281) 342-0297 fax (281) 341-6006
e-mail [email protected]

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
tel. +44 1722 410055 fax +44 1722 410088
e-mail [email protected]
http://www.fwmurphy.co.uk

FRANK W. MURPHY FRANCE

tel. +33 1 30 762626 fax +33 1 30 763989

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
tel. +52-48-206264 fax +52-48-206336
e-mail [email protected]

FRANK W. MURPHY PTE., LTD.

No. 2 Tuas South Street 2,
Sprintecs Bldg., #02-01/02
Singapore 638042
tel. +65 863-1398 fax +65 863-0208
e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MURPHY SWITCH OF CALIFORNIA

41343 12th Street West
Palmdale, California 93551-1442; USA
tel. (661) 272-4700 fax (661) 947-7570
e-mail [email protected]
http://www.murphyswitch.com

MACQUARRIE CORPORATION

1620 Hume Highway;
Campbellfield, Vic 3061; Australia
tel. +61 3 9358-5555 fax +61 3 9358-5558
e-mail [email protected]

FRANK W. MURPHY MANUFACTURER P.O. Box 470248; Tulsa, Oklahoma 74147; USA tel. (918) 627-3550 fax (918) 664-6146 e-mail [email protected] http://www.fwmurphy.com

BSI

R

E

G

IS

T ERED

F

IR

M

FM 28221

FM 29422

USA–ISO 9001

UK–ISO 9002

NATIONAL

ACCREDITATION

OF CERTIFICATION

BODIES

Since 1939

Advertising