Do s dont' s, Nw14/nw35, Mvc1 – M&S Systems MC111M/DM User Manual

Page 3: Nwrc14, Ns3/ns3b, Bd3/d3/bd3b/d3b, Awpm, Aster, Peakers, Atio speakers

Advertising
background image

M

ASTER

U

NIT

Locate an NMR5 mounting ring for the master unit. Position
the mounting ring approximately 52” high. Have a qualified
electrician run a
d e d i c a t e d
1 2 0 VA C / 6 0 H z
receptacle

with

ground connection
from the power
panel to a remote
junction box in
which to mount the
RT35

power

transformer. Install
and connect the
remote

power

transformer

as

shown in Figure
1 and Figure 2.
Use

Figure

1

and Figure 3 for
plug-in version using
RT11.

S

PEAKERS

N14, N35, N15D

At each room station location, nail or
screw the NMR5 mounting ring (for
N14, N35, N15D or NWRC14) to a
vertical wall stud approximately 52”
above the floor. RETROFIT: locate
mounting rings at least 1” from studs.
From the master unit location, run
MS4XSC cable to each remote station
location. Secure approximately 12” of
wire at the speaker location to protect
wire from dry wall damage. Secure
cables at the master.

P

ATIO SPEAKERS

NW14/NW35

Run a single cable MS4XSC from the master unit location to
each

outdoor

speaker location
and secure the
cable to the correct
plastic or metal
enclosure

by

wrapping the cable
around a small
piece of wood.
Use

NME5

enclosure

for

recessed NW14 or
NW35

patio

stations.

S

ATELLITE

S

PEAKERS USING

MVC1

VOLUME CONTROL

At each room
station location,
nail a single gang
box for the
MVC1 volume
control to a
vertical

stud

approximately
52” above the
f l o o r .
RETROFIT: use
a single gang
box

designed

for

existing

construction.

Careful consideration should be used when determining wall housing
location. DO NOT install wall housing in the following locations

:

DO NOT Install wall housing in return air ducts.

DO NOT install wall housing in exterior walls

DO NOT Install wall housing underneath cabinets or over counter

tops.

DO NOT install wall housing in stud cavities with other 120/240

appliances.

DO NOT install wall housing within 18” of dimmers, fluorescent

light fixtures, security wiring and other control wiring.

DO NOT install wall housing within 2” of room corners.

DO make sure all mounting rings are level and oriented as

shown in these instructions.

DO

s

DONT'

s

&

Generally, existing type single gang boxes will mount between
vertical studs at least 1” from studs. From the master unit wall
housing, run MS4XSC cable to each remote station location.
Secure approximately 12” of wire at the speaker location
to protect wire from dry wall damage. Secure cables at the
master. Note: No more than 2 satellite speakers can be
connected to the MVC1.

R

EMOTE

C

ONTROLS USING

NWRC14

At each room
station location,
nail an NMR5
mounting ring
to a vertical
s

t

u

d

approximately
52” above the
floor. From the
master unit wall
housing,

run

MS4XSC cable
to each remote
station location.
S e c u r e
approximately
12” of wire at the speaker location to protect from dry wall
damage. Secure cables at the master. Note: No more than 2
satellite speakers can be connected to the NWRC14.

D

OOR

S

TATIONS

NS3/NS3B &

BD3/D3/BD3B/D3B

Run MS4DCXSC or
from the master unit
location to each door
station.

Allow

18

inches of excess cable
on each end. On the
door speaker end,
suspend

the

ME3

metal enclosure on
the cable about 50
inches above the floor
(porch) so the brick
mason can flush and
level it in the brick
wall. If wood or
aluminum siding is used, secure surface mount housing SMP3
(for NS3B series) or SME3D (for BD3B/D3B series) to the
finished wall using galvanized screws. Secure cables at master.

E

XTERNAL

M

USIC

S

OURCE

AWPM

External

Music

Sources

(AWPM): Choose a location
for the AWPM that will
be easily accessible to the
sources that are to be
connected to the system
(close to the stereo receiver,
TV or VCR for example). At
this location, attach a single
gang box to a wall stud at a
center height of normal wall
outlets. Make sure the single
gang box extends past the
wall stud and into the room so it will be flush with the
sheetrock when it is applied. Run the Red or Black shielded
audio cable (included in the AWPMRX) from the master unit
location to the AWPM location. Note: Only one cable is
required for use with the MC111M/DM.
Secure the audio
cable with a loose knot after it has been pulled through the
single gang box. Secure the cable at the master.

D

OOR

R

ELEASE

O

PTIONS

Door or Gate release mechanism: Run a single line of
VM127X from the master unit location to the door release
mechanism and to each N15D/N35D remote station. Do
not bundle the VM127X wires with the intercom wires!
Connect
the Red and White wires to the two wires or terminals of the
door release mechanism. Run another single line of VM127X
from the master unit location to a gang box next to a 120VAC

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,ROUGH-IN,MC111 - LINEAR P/N: 115741 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT: 17.000” X 11.000”, FOLDED 8.500” X 11.000” - SCALE: 1-1 - FOLDING: 1-FOLD VERTICAL - SIDE 2 OF 2

Figure 2 - RT35 Power transformer hookup

Figure 3 - RT11 Power transformer hookup

Figure 1 - Power transformer wiring diagram

n

o

i

t

a

c

o

l

r

e

t

s

a

m

o

t

s

w

e

r

c

s

ll

a

w

y

r

d

e

l

b

a

c

d

u

t

s

)

t

u

o

e

d

i

s

d

e

m

r

o

f

(

g

n

i

r

g

n

i

t

n

u

o

m

C

S

X

4

S

M

Figure 4 - Remote

station Rough-in

P

U

k

c

o

l

b

d

n

u

o

r

a

e

r

i

w

p

a

r

w

5

E

M

N

g

n

i

h

t

a

e

h

S

k

c

o

l

b

d

o

o

W

Figure 6 - Recessed patio

speaker mounting

Figure 5 - NME5

recessed enclosure

Figure 7 - Remote station with satellite speaker

Figure 8 - Remote Intercom station with satellite speaker

P

U

Figure 9 - Recessed door station rough-in

Figure 10 - ME3

enclosure for all door

stations

Figure 11 - SME3D

surface mount

enclosure

Figure 12 - SMP3

surface mount

enclosure

Figure 13 - AWPMRX installation

The door release option is a momentary normally open dry
contact closure provided by the master and door release
equipped remote stations and remote controls. This dry
contact is rated 24V at 1 Amps. The sample applications
below represent some uses. However, only one application
can be used in any MC111DM system at a time.