How to perform a leak test:

Supplies Needed for a Leak Test: Clean paint
brush, water, and dish washing liquid.

1) Use a 1 pound disposable LP Cylinder.
2) Make sure the control knobs to grill and

accessories are turned to the “off” position.

4) Mix one part of water with one part of dish

washing liquid.

5) Connect LP cylinders to the main grill burner,

the side table burner and the lantern.

6) Check for leaks by brushing the soap solution

on all LP gas connections and fittings indicated
by the heavy arrows in (FIG. 12A-2D) Make
sure you generously brush the locations with
the soap solution, completely surrounding the
connections and fittings.

7) If “growing” bubbles appear on any of the

connection points, you have detected a gas
leak. Immediately disconnect the LP cylinder.

A) If leak appears at either end of hose and

regulator assembly, retighten the connection at
the leak, but do not over tighten.
(Note: Only hand tighten cylinder connections.)
Repeat Leak Test.

B) If the leak is coming from the LP gas

cylinder itself, from the valves at the control
knobs, or if the leak cannot be stopped, do not
use the grill. Call Customer Service at 1-800-
251-7558.

8) Upon completion of leak test:

A) Turn all control knobs to the “Off” position.

B) Disconnect LP cylinders from the

connections to the Main Grill Burner, Side
Burner and Lantern.

9) Place the protective cap over the LP cylinder

gas nozzles. Store the cylinders in a safe
place.

FIG. 12B

FIG. 12C

Leak Test Side Burner Connections

Leak Test Lantern

Connections

When used

on the grill.

When used as

portable lantern.

FIG. 12D

PERFORMING A LEAK TEST

To reduce the risk of serious bodily injury or death:

· Always perform a leak test before each use.
· Never use a match or open flame to test for gas leaks.
· Perform a leak test in a well ventilated area.
· Do not perform a leak test on a grill while it is hot or

in use.

· Do not use the LP gas grill if you detect a gas leak

that cannot be corrected by using the leak test
procedures on following page.

FIG. 12A

Leak Test Main Burner Connections