F: Excessive Frost Build-Up:

Note: This is the result of moist air being allowed to enter the box. Problems are
compounded when cold air leaks from the lower area of the box & is replaced by warm,
humid air entering elsewhere.

1 Drains & holes not

plugged

Make sure all drains & holes in the
floor & walls of the box are sealed.

2 Circulating fan

If a small fan is used to circulate air in
the box, make sure that the cold air is
not being blown towards & out of a
door/lid seal. This could force cold air
out of the box & set up a circulation
pattern if the seals are leaking

2 Poor or damaged door/lid

seals

Check seals & replace if necessary. A
good seal will grip a $1 bill when
inserted in the seal & the door/lid is
then closed. A front opening door / top
opening lid combination with poor seals
is likely to result in excessive frost
build-up on the evaporator, & extended
run times.