1 typical current profiles, Figure 1, Typical 5v startup and operation current profile – Maxtor DIAMONDMAX 100451230 User Manual

Page 25

Advertising
background image

DiamondMax 21 Serial ATA Product Manual, Rev. A

17

• Operating power and current

Operating power is measured using 40 percent random seeks, 40 percent read/write mode (1 write for each
10 reads) and 20 percent drive idle mode.

• Idle mode power

Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in
a random track location.

• Standby mode

During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/
write electronics are in power-down mode.

Table 6:

DC power requirements

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and

power to operational levels.

2.8.1.1

Typical current profiles

Figure 1. Typical 5V startup and operation current profile

Power dissipation

Avg (watts 25° C)

Avg 5V typ amps

Avg 12V typ amps

Spinup

2.8 (peak)

Idle*

9.30

0.611

0.520

Idle* (with offline activity)

10.40

0.719

0.567

Operating (40% r/w, 40% seek, 20% inop.)

13.00

0.772

0.762

Seeking (random, 20% idle)

12.60

0.613

0.795

Standby

0.80

0.106

0.023

Sleep

0.80

0.106

0.023

Advertising