Forward path, Return path, Ble100 installation and operation manual – Motorola BLE100 User Manual

Page 18

Advertising
background image

Overview 2-7

BLE100 Installation and Operation Manual

Forward Path

The operational gain of the BLE100 amplifiers is 34 dB with 16 dB of return loss. The operating
gain includes provisions for the insertion loss of the input cable equalizer and required reserve
gain to operate the Bode equalizer in the middle of its range. The low-noise figure, pre-amplifier
stage, is a 1 GHz hybrid followed by a power-doubled output stage. Between the two stages is a
JXP-*B pad socket, the Bode board, and the flatness and equalizer board. Because these losses
are located interstage, the noise figure is only significantly impacted by the insertion loss of the
forward cable equalizer or broadband cable simulator, and the input pad if its value is increased
from zero.

Figure 2-7 illustrates the interconnection among these components:

Figure 2-7
BLE100 block diagram

24 Vdc

DC test point

Power
supply

Input
port

JXP-B

-16 dB

JXP-B

LPF

BODE

RC

Therm

PP

PD

TP

-20 dB

AC test

point

JXP-B

Manual

LDR

H

L

-20 dB

TP

Auto

ICS

JXP

TP

-20 dB

Power

Block

Jumper

** Plug-in module

FTEC

Status

monitor

Surge

protector

Surge

protector

SFE

or

SCS

JXP-B-

-1.0 dB

-1.0 dB

-1.0 dB

28 dB

-6.5 dB

-1.0 dB

-1.0 dB

-1.0 dB

SRE

-0.5 dB

+30.0 dB -0.3 dB

-0.4 dB

-0.4 dB

-0.4 dB

RF

RF/
AC

AC

-1.7
dB F

-1.0
dB R

23 dB

TP

Return

injection point

-20 dB

OnBrd

Atten

~ -3 dB

Output

port

H

L

RF/

AC

AC

RF

-1.7

dB F

-1.0

dB R

JXP-B

OnBrd

Atten

ADU/

TDU

Fuse

Return Path

The circuit board of the BLE100 includes the return path. This equips the BLE100 to pass
signals in the return or upstream direction. The standard circuit board contains all components
including the diplex filters with extended return bandwidth for the amplifier input and output.

Optional SRE-*-* return equalizers compensate for cable attenuation and are available in 1 dB
increments for S-split, and 2 dB increments for all other splits, from 0 dB through 12 dB.