MICRONAIR AU8000 SPRAYER

Fig. 3 – Coverage of Sprayer



3. Calculate the area treated by the sprayer per minute. Fig. 3 shows the sprayer being

operated over a field crop.

If the operator is walking at S Km/Hr this corresponds to 1000 x S metres/hour:

Distance travelled

=

1000 x S metres/minute

60

If the width of the swath is W metres, then the area treated per minute is:

Area treated

=

1000 x S x W

sq metres/minute

60

This is converted to hectares by dividing by 10,000:

Area treated

=

1000 x S x W

=

S x W ha/minute

60 x 10,000

600

This gives the standard formula for calculating the coverage of a sprayer:

Area/min

=

Swath Width (m) x Speed (Km/Hr) ha/min

600