Micron Technology AU8000 User Manual

Page 12

Advertising
background image

10

MICRONAIR AU8000 SPRAYER

Example:

Speed: 4

Km/Hour

Swath

Width:

12

m

Therefore:

Area treated

=

S x W

4 x 12 =

0.08

ha/min

600

600

Table 1 shows the coverage of the sprayer for various swath widths and spraying
speeds.

4. Calculate

the

required output from the sprayer in litres/minute to give the correct

application rate for the chemical being used.
The output rate of chemical is given by the area sprayed (in hectares) per minute
multiplied by the required application rate in litres per hectare.

Example:

Coverage:

0.08

ha/min

Application

rate:

2

litre/ha

Output =

0.08 x 2 = 0.16 litre/min

SWATH WIDTH (METRES)

Speed

Km/hr

2 5 10 15 20 25 30 50

2

0.007 0.017 0.033 0.050 0.067 0.083 0.100 0.167

3

0.010 0.025 0.050 0.075 0.100 0.125 0.150 0.250

4

0.013 0.033 0.067 0.100 0.133 0.167 0.200 0.333

5

0.017 0.047 0.083 0.125 0.167 0.208 0.250 0.416

Table 1 – Coverage of Sprayer in Ha/min


5. Select the correct restrictor tube to give the required flow rate. Table 2 gives the

typical flow rate for each restrictor tube both with gravity feed and with the optional
boost pump operating. These figures are based on measurements with water. Actual
flow rates will depend upon the viscosity of the chemical being used. When the boost
pump is not used, the flow rate will also be affected by the height of the sprayhead
relative to the chemical tank. The rates in Table 2 are measured with the tank half full
and the sprayhead level with the engine.


FLOW RATE (LITRES/MINUTE)

RESTRICTOR

NUMBER

Without boost pump

With boost pump

1

0.075 0.40

2

0.150 0.80

3

0.300 1.60

4

0.600

5

1.200

Table 2 – Approximate Flow Rates for Restrictor Tubes