For Canadian installation in both flush and down-

rod mode the safety cable must be installed into

the house structure beams using the 3” lag screws

provided. Make sure that when the safety cable is

fully extended the leadwires are longer than the

cable and no stress is placed on the leadwires.

Hang assembled fan from the mounting bracket

installed to ceiling in previous step. Make sure the

fan is hanging straight. Rotate fan until the tab on

the Mounting bracket engages the slot on the

Downrod Ball. This must be done to prevent the fan

body from rotating when the blades are in motion.

7

8

Make wire connections to power source using wire nuts
provided. Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on
the other side of the outlet box.

CCaannaaddiiaann m

moouunnttiinngg oonnllyy

Safety Cable

Lag Screw

11

Make sure the studs protruding from the

bottom of the Mounting bracket are

installed with threads all the way through

the bracket.

9

Pass leadwires and safety cable

through the canopy.

Remove side covers from canopy expos-

ing 4 holes. 2 closed holes and 2 open

“L” shape holes.

16

FFlluusshh M

Moouunntt IInnssttaallllaattiioonn

15

Lift Canopy allowing the 2 studs to

protrude through the canopy.

12

Next lift the canopy disk and install

knurled nuts as shown. Tighten the

knurled nuts securely. The canopy should

adjust for any irregularity in the ceiling or

Outlet box.

13

Connect black and blue wire from fan to Black or (Hot)

wire from house. Connect White wire from Fan to

White (Neutral) wire from house. Connect Ground

leads from mounting bracket and downrod to Ground

lead from house. Refer to Safety Tips section of

manual.

10

Canopy disk

House

Fan

Blue

Black

White

Green

Black

White

Ground

Lag Screw

Washer

Lock Washer

Safety Cable

Go to Step 26

14

Install rubber pad between fan

body and canopy.

18

Remove every other screw as circled

and save for later use.

17

Advertising