Change the gaskets 42, Change the gaskets, Coffee system care – Miele CVA 615 User Manual

Page 42: Resetting the brew unit’s basic position

Advertising
background image

Resetting the brew unit’s basic
position:

^ Press on the latch, a, and press the

funnel down,

b.

^ Push the connection piece to the far

left,

c.

^ Press "PRESS" once.

The basic position shown above is
reset and the brew unit can be set back
into the machine.

Change the gaskets

^ If a leak occurs change the gaskets.

Three gaskets are enclosed with the
machine. One gasket is located
between the steam valve and the
sleeve. The other two gaskets are
located behind the brew unit at the
water feed tube.

Coffee system care

42

Advertising