c.
Route customer supplied 18 gauge/2-conductor cord under cross member below door.
d.
Make cord connections to terminal strip common and the Weld Alarm terminal.
e.
Close robot control unit door, and route cord to jig interface.
f.
Connect cord to isolation relay coil and voltage source.
g.
Cut
off
terminals from one end
of
supplied 18 gauge/2-conductor cord, and install terminals to connect
to
contacts
on isolation relay.
h.
Connect one end of cord to a set of normally-open contacts on isolation relay.
i.
Route cord through strain relief on
rear
panel of computer interface.
j.
Connect cord
to 2TF and
2TG.
Add Figure 2-4. Arc Failure Light Connections
JIg TermInal
StrIp 2
Common
Robot
Control
unit
Weld Alarm
Computer Interface
2W
2TG
To Voltage Source
(115VAC,
24VAC,
24VDC)
I
Figure 2-4. Arc Failure LIght Connections
Arc
FaIlure
Indicator
Ught
Robot
Control
Unit
0
2TF
~—
Alarm
JIg Interface
Arc Failure
IndIcator
Light
computer
Interface
TA-i 15 648
OM-882 Page 2