Options, Additional communications options – MGE UPS Systems Pulsar TM EX20 User Manual

Page 7

Advertising
background image

MGE UPS SYSTEMS

Pulsar EX : 51032278XT/AB

v

c

front panel LEDs signal all types of faults

and alarms;

c

Bar graph continuously indicates the

battery charge level or the critical load
power level;

c

Pulsar EX20 and EX30 are environment

friendly: all components are recyclable and
an electronic power-saver device reduces
power consumption if the UPS is not active
for a period exceeding 5 minutes while on
battery back-up;

c

EX Driver software provides rapid startup

of Pulsar EX20 and EX30 using the EX
Tuner configuration module. This module
adapts Pulsar EX20 and EX30 to user
preferences (battery test frequency, startup
and shutdown sequences, setting of battery
thresholds, etc.). Operation and monitoring
are ensured by the UPS Manager 3.1
module operating under Windows 3.1.
EX Driver connects to the RS 232 port on
the Pulsar EX20 and EX30 (see
"communication" section for further details);

c

Solution-Pac

TM

is a CD-ROM which

contains all the tools needed to supervise
your UPS.

options

c

rack installation kit: this kit is used to

install Pulsar EX20 and EX30 in a 19-inch
rack;

c

UM Sensor environment measurement

unit: compatible with SNMP and UPS
Manager 2 Unix and OS/2, or Solution
Pac

TM

, this unit measures the temperature

and the relative humidity in the room where
the Pulsar is installed. Eight relay contacts
are provided to transmit signals to an
administration platform, in the form of
voltage-free contacts to enable monitoring of
(fire alarm, climate control fault, intrusion,
etc.);

c

battery extension module: Pulsar

EXB20/30 battery extension modules
lengthen the battery time of the Pulsar
EX20/EX30
to meet your requirements;

c

isolation transformer: input line cord

plugs into the Pulsar EX30 output
receptacle. Rating is 120V AC input, 208V/
240V AC 2.75 kVA output;

c

maintenance bypass switch: enables

the user to continue supplying ac power to
the load while performing routine or
emergency maintenance.

additional communications
options:

c

communication cables: these cables are

used for the file-closing utilities offered by a
number of network operating systems. They
are available for Novell NetWare, Microsoft
Lan Manager and Windows NT, IBM Lan
Server, Artisoft LANtastic, Banyan Vines,
Apple System 7, IBM AS400 and many
others;

c

UPS Manager 2 communication

software: this software can be used for
automatic file closing on one or more
servers, as well as for remote UPS
shutdown and interrogation of all Pulsar
EX20
and EX30 operating parameters. It is
available for Novell NetWare, Microsoft Lan
Manager, IBM Lan Server, the main Unix
systems on the market (SCO, AIX, HP/UX,
OSF 1, etc.) VAX UMS and many others;

c

SNMP administration: Merlin Gerin has

the most complete offering for the
administration of a group of UPSs using the
SNMP protocol with different network-
connection modules (UM Link adaptor or
proxy UM Agent software), supervision
modules (dedicated software under
Windows UM View or application for NMS
platforms such as HP OpenView or Novell
NMS) and a file-closing module (UM Client).
The MGE UPS SYSTEMS offering complies
with RFC 1628 specifications (IETF) and
was certified by the InterWorking Labs
during the Test Summit in June 1994;

c

SNMP card: this card, inserted into your

unit, makes your UPS SNMP-compatible in
any environment;

c

status information card: this option

provides you with 5 voltage-free contacts: on
battery, on by-pass, low battery, load on
UPS.

Contact your dealer for further information
on these options.

Advertising
This manual is related to the following products: