Chapter 4 - hardware removal/replacement, Disconnecting cables and removal from enclosure, Chapter 4 - hardware removal/ replacement – Multi-Tech Systems Hub User Manual

Page 18

Advertising
background image

18

CommPlete 4000 Communications Server User Guide

Chapter 4 - Hardware removal/ Replacement

Chapter 4 - Hardware removal/Replacement

This chapter’s procedures describe removal and replacement of the main hardware components of
the CommPlete 4000. Before removing or replacing any component, disconnect the cables from the
back of the CommPlete 4000 and remove the CommPlete 4000 from its rack enclosure per
instructions. The CommPlete 4000 has been designed to make this process as efficient as possible,
but if you experience problems, contact Multi-Tech Technical Support (see chapter 6 of this section).

Disconnecting Cables and Removal from Enclosure

The steps below describe how to remove the CommPlete 4000 from its rack enclosure. These steps
must be followed before any internal component can be removed or replaced.

Warning: Anytime power is removed, turn off the Master Power switch inside the front door.

Note: In order to make re-connection easier, be sure to note or label all cable connections
before disconnecting any cables from the CommPlete 4000.

1

Remove the power cord from the back of the CommPlete 4000.

2

If connected, disconnect the video, COM 1, keyboard, and network cables from the back of the

SBC.

ISI Boards

120

Cover Mounting
Screws

Cover

COM 2
(DB15)

Printer Port
(DB25)

SBC Backplane

Power Supply

MODEM

Line

1-4

MODEM

Line

1-4

MODEM

Line

5-8

MODEM

Line

5-8

Fig.4-1. Back Panel Connectors

3

Disconnect the telephone cords (RJ-12 and/or RJ-45) from the serial interface card(s).

Note: You may have ISI boards located in the left and right halves of the card cage

Caution: For safety and proper handling, two people are required to remove the CommPlete
4000

from its rack enclosure. Please work safely.

4

Remove the four rack enclosure mounting screws from the front of CommPlete 4000 and

remove the CommPlete 4000 from the rack enclosure. See Figure 4-2.

Handle

Enclosure

Mounting Holes

Fan Intake Vents

Rack Enclosure

Mounting

Screws

Single Processor
Communications Server

Fig. 4-2. Rack Enclosure Mounting Screws