Board removal and replacement, Removing sbc board, 21 chapter 4 - hardware removal/replacement – Multi-Tech Systems Hub User Manual

Page 21

Advertising
background image

CommPlete 4000 Communications Server User Guide

21

Chapter 4 - Hardware removal/Replacement

Board Removal and Replacement

Removing SBC Board

1

Remove the CommPlete 4000

from rack enclosure (two people are needed). Follow the

procedure “Disconnecting Cables and Removal from Enclosure” presented above. Summary:
after powering down the unit and disconnecting all power and signal cables, employ two persons
to remove its rack-mounting screws and lift the unit out of the rack.

2

Remove the top cover from the CommPlete 4000

by removing the seven cover mounting

screws located in the back of the CommPlete 4000. (See Figure 4-3.)

3

Disconnect the four ribbon cables from the SBC. (See Figure 4-6.) Depending on

your configuration, you may not have all four ports in use.

COMA1

LANB1

USBF2

KCN1

PKM1

VGAA1

SC2T2

COMB1

LNB1

SM1

PLRS1

LPTA1

IDEB1

FDCA1

ATXD1

SC2T1

USBF1

FAN1

SCF1

PSW1

LVDSE1

VLCD1

IDEB2

KBPW1

South

Bridge

North

Bridge

CMOS1

IRDA1

DIMMA1 DIMMA2 DIMMA3

SBVB1

SLVA1

FAN2

CPU

Figure 4-6. SBC Board and Ribbon Cable Connectors

4

Remove the fanned heatsink from the processor or disconnect the power connector for the

fanned heatsink.

5

Remove the screw that secures the SBC board to the chassis at the back of the CommPlete

4000.

6

Remove the SBC board from the midplane.

7

To replace the SBC board, verify SBC board configuration. Refer to the Hardware

Configuration and Installation instructions in the SBC manual.

8

Install the new SBC board by following steps 1-5 in reverse order and sense. That is,

a. Attach SBC to its midplane socket.

b. Secure SBC to rear of chassis with screw.

c. Re-connect ribbon cables and fanned heatsink.

d. Replace top cover (7 screws).

e. (Two people are needed.) Replace CommPlete 4000 into rack enclosure.

Advertising