English – Middleby Marshall PS314SBI User Manual

Page 19

Advertising
background image

19

ENGLISH

Figure 4-3 - Disassembling the Air Fingers

Pull outer plate

straight up

and off

Manifold

Inner plate

Outer Plate

2

Step on lip of manifold

1

Swing ends of inner plate and

manifold apart

3

Pull inner plate

upwards, and

then away from

manifold

4

SECTION 4 - MAINTENANCE

7. Disassemble the air fingers as shown in Figure 4-3. AS

EACH FINGER IS DISASSEMBLED, WRITE THE "LOCA-

TION CODE" FOR THE FINGER ON ALL THREE OF ITS

PIECES. This will help you in correctly reassembling the

air fingers.
CAUTION

Incorrect reassembly of the air fingers will change the

baking properties of the oven.

8. Clean the air finger components and the interior of the

baking chamber using a vacuum cleaner and a damp cloth.

Refer to the boxed warnings on Page 17 for cleaning

precautions.

9. Reassemble the air fingers. Then, replace them in the

oven, using the "location code" as a guide.

10. Replace the end plugs on the oven.
11. Reassemble the conveyor into the oven.
12. Reattach the drive chain. If the motor was repositioned to

allow the chain to be removed, adjust the tension of the

chain to the proper 1/2" (13mm) deflection. Refer to Step

3 of the Conveyor Installation instructions (on Page 9).

13. Check that the conveyor belt has the proper 2-3" (50-75mm)

deflection. If it is necessary to adjust the tension of the belt,

refer to Steps 4-6 of the Conveyor Installation instructions

(on Page 9).

14. Replace the drive motor shroud and the conveyor extensions.

III. MAINTENANCE - EVERY 3 MONTHS

1. Check that the oven is cool and the power is disconnected,

as described in the warning on Page 17.

2. Vacuum both of the blower motors, and their surrounding

compartments, using a shop vacuum.

3. Tighten all electrical control terminal screws.

IV. MAINTENANCE - EVERY 6 MONTHS

1. Check that the oven is cool and the power is disconnected,

as described in the warning on Page 17.

2. Check for excessive wear on the conveyor drive motor

brushes. The brushes should be replaced if they have worn

to less than 1/4" (6.4mm) in length.

3. Clean and inspect the burner nozzle and electrode assembly.
4. Check (and clean, if necessary) the oven venting system,

including the flue.

5. Check the conveyor drive shaft bushings and spacers.

Replace the components if they are worn.

V. MAINTENANCE - EVERY 12 MONTHS

1. Remove the motor shroud and the drive-end conveyor

extension cover.

2. Disconnect the drive chain as described in Step 3 of the

Monthly Maintenance section (on Page 18).

3. Use a grease gun to lubricate the drive shaft bearings, as

shown in Figure 4-4. When lubricating the bearings:
•

Use a high-quality NLGI #2, lithium soap grease with

petroleum oil, such as Middleby P/N 17110-0015.

•

Add the grease slowly until a small bead of grease is

present at the seals. AVOID OVERGREASING.

Excessive greasing may cause harm to the bearing.

4. Manually turn the drive shaft by pulling on the conveyor belt

to purge the grease.

5. Wipe off any excess grease on and around the bearings.
6. Reattach the drive chain. If the motor was repositioned to

allow the chain to be removed, adjust the tension of the

chain to the proper 1/2" (13mm) deflection. Refer to Step

3 of the Conveyor Installation instructions (on Page 9).

7. Replace the motor shroud and conveyor extension cover.

Figure 4-4 - Lubricating the Bearings

Grease fitting

(1 per bearing, 2 total)

Advertising