Panel/wall mounting, Din-rail mounting (optional) – Moxa Technologies Moxa ToughNet Switch TN-5308 User Manual

Page 6

Advertising
background image

— 5 —

Panel/Wall Mounting

Mounting the TN-5308-LV/MV on the wall requires 3 screws. Please use the
3 screws packed in the panel mounting kit.

STEP 1: Prepare the 3 screw holes on the wall according to the positions of
the 3 screw holes on the switch shown on the mounting dimension diagram.

STEP 2: Use one screw to go through the top-middle screw hole on the
switch and screw it into the wall.

STEP 3: Screw in the remaining 2 screws through the bottom-left and
bottom-right holes on the switch to the wall.

NOTE The screw lengths of TN-5308-LV and TN-5308-MV are

different. TN-5308-LV uses M3 * 30 mm screws. TN-5308-MV
uses M3 * 40 mm screws. Please use the screws packed in the
panel mounting kit.

DIN-Rail Mounting (optional)

With the optional DIN-Rail mounting kit
DK-TN-5308 (must be purchased separately),
you can mount the TN-5308-LV/MV on a
35mm DIN-Rail.

STEP 1:

Fix the DIN-Rail attachment plate onto the rear
panel of the switch as shown in the figure at the
right.

STEP 2:

Position the TN-5308-LV/MV on the
DIN-Rail, tilting to hook clamps over
the top edge of the rail.

STEP 3:

Swing the switch down fully onto the
DIN-Rail until both clamps completely
latch.

metal
spring

DIN-Rail

metal
spring

DIN-Rail

To remove the Moxa ToughNet Switch from the DIN-Rail, simply reverse
Steps 2 and 3 above.