Connecting the data lines – Moxa Technologies Moxa ToughNet Switch TN-5308 User Manual

Page 9

Advertising
background image

— 8 —

Connecting the Data Lines

10/100BaseT(X) Ethernet Port Connection

All TN-5308 models have 8 10/100BaseT(X) Ethernet ports (4-pin shielded
M12 connectors with D coding). The 10/100TX ports located on the
TN-5308’s front panel are used to connect to Ethernet-enabled devices. Most
users configure these ports for Auto MDI/MDI-X mode, in which case the
port’s pinouts are adjusted automatically depending on the type of Ethernet
cable used (straight-through or cross-over), and the type of device (NIC-type
or HUB/Switch-type) connected to the port.

In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for
straight-through and cross-over Ethernet cables.

Pinouts for the 10/100BaseT(X) Ports on the TN-5308

Housing: shield

Pinouts for the RJ45 (8-pin) Port

RJ45 (8-Pin)

MDI Port Pinouts

MDI-X Port Pinouts

1

8

Pin Signal

1 Tx

+

2 Tx

-

3 Rx

+

6 Rx

-

Pin Signal

1 Rx

+

2 Rx

-

3 Tx

+

6 Tx

-

M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring

Tx+
Rx+
Tx-
Rx-

Cross-Over Cable Wiring

1
2
3
4

1
2
3
4

Tx+
Rx+
Tx-
Rx-