Loor, Rotection – Monessen Hearth BWB400 User Manual

Page 10

Advertising
background image

10

F

LOOR

P

ROTECTION

If this fireplace is installed on a combustible floor, the floor area 16 inches in front of, and 8 inches either side
of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth
extension may be either minimum 6-inch thick stone or brick as shown by Figure 10, a H1652 Hearth Extension
Kit or a locally constructed hearth equivalent which has a "K" factor less than .43.

8"

8"

MIN.

16"

16"

MIN.

6"

6"

MIN.

DO NOT BLOCK
LOUVERED OPENINGS

EXTENSION

52

52

"

LONG MIN.

FIREPLACE

HEARTH

METAL SAFETY STRIP

PLATFORM

ALTERNATE BRICK OR STONE HEARTH EXTENSION

FOR USE WITH SCF36A/SCF36AI FIREPLACES.

16"

16"

MIN.

FIREPLACE

HEARTH

SAFETY STRIP REQUIRED WHEN UNIT IS PLACED
ON COMBUSTIBLE FLOOR OR PLATFORM

DO NOT PLACE HEARTH MATERIALS
ABOVE OPENING OF FIREPLACE.

6"

6"

MIN.

ALTERNATE BRICK OR STONE HEARTH EXTENSION

FOR USE WITH SF36A/SF36AI FIREPLACES.

8"

8"

MIN.

6"

6"

MIN. OF BRICK

OR STONE FROM TOP

OF PLATFORM.

8"

8"

MIN.

DO NOT PLACE HEARTH
MATERIALS ABOVE
OPENING OF FIREPLACE.

HEARTH

FIREPLACE

PLATFORM MAY EXTEND UNDER
HEARTH EXTENSION IF DESIRED

METAL SAFETY STRIP

PLATFORM

BRICK OR STONE HEARTH

EXTENSION

52

52

"

LONG MIN.

BRICK OR STONE HEARTH

EXTENSION

52

52

"

LONG MIN.

BRICK OR STONE HEARTH

F

IGURE

10

53D9031. Rev 1 03/03