Installing the Power Supply

Follow the steps outlined below to install the ACPS-17HS or
DCPS-17HS power supply in the Radiance R5000 Central
Service Platform.

IMPORTANT

Disconnect all power sources before

installing or removing the power supply.

A blank panel must remain installed in any

empty power supply slot.

Do not apply power to the power supply

while it is out of the platform.

1. Remove the blank panel from the back of the platform.
2. Insert the power supply into the slot. Do not force it into

the platform unnecessarily. It should slide in easily and
evenly.

3. Push gently until the face panel is flush with the platform.
4. Turn the thumb screws clockwise and tighten to secure the

power supply into the platform.

Applying Power

DC Power Supply (DCPS-17HS)
For DC power supply connections, follow these guidelines:
• Make sure the power switch is in the OFF position

(O)

.

• Remove the plastic safety cover to expose the terminals.
• Connect the wire leads to the appropriate terminals. There

is one each for a positive, a negative and a platform
ground. To make a connection, loosen the terminal screw,
insert the exposed wire, then tighten the screw. If two
power supplies have been installed, connect each power
supply to a separate power source.

• Replace the plastic safety cover over the terminal block.
• Set the power switch to the ON position

(I)

.

• Verify proper connection and operation via the power

(PWR) LED on the power supply front panel. The LED is
lit when the power supply is functioning correctly.

Important: The terminal block safety cover must be installed
when power is present to prevent burn or energy hazards.

Caution: A fully loaded platform is rated for 4.9A DC
maximum current. Make sure that the power supply current
available is sufficient to power the platform. Refer to front
panel text for voltage/current ratings. The center terminal
connector provides grounding for the platform and must be
maintained. Particular attention should be given to power
supply connections other than direct connections to the
branch circuit (e.g. use of power strips).

Note: The DCPS-17HS is designed to protect against
overheating. The power supply will go into thermal shut-
down mode if it is operated above the specified temperature
of 50

°

C. Normal operation can be reestablished once the

temperature drops to the specified range by power cycling
the unit.

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

FACTORY DEFAULT

SETTING 115V

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

AC IN

100-120 /
200-240V

50-60Hz

2A

CAUTION

WARNING

PWR

ACPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

FACTORY DEFAULT

SETTING 115V

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

AC IN

100-120 /
200-240V

50-60Hz

2A

CAUTION

WARNING

PWR

ACPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

R5000-17HS

_________________
PRODUCT SERVICE

_________________
PRODUCT SERVICE

For AC power supply connections, follow these guidelines:
• Make sure the power switch is in the OFF position

(O)

.

• Plug the AC cord into the connector on the power supply,

then insert the other end of the cord into the AC power
source. If two power supplies have been installed, connect
each power supply to a separate power source.

• Set the power switch to the ON position

(I)

.

• Verify proper connection and operation via the power

(PWR) LED on the power supply front panel. The LED is
lit when the power supply is functioning correctly.

Caution: A fully loaded platform is rated for 2A AC
maximum current. Make sure that the power supply current is
sufficient to power the platform. Refer to the front panel text
for voltage/current ratings. Reliable grounding of rackmount
equipment must be maintained. Particular attention should
be given to power supply connections other than direct
connections to the branch circuit (e.g. use of power strips).

DC IN 48V, 4.9A

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

CAUTION

PWR

DCPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

Made in

USA

DC IN 48V, 4.9A

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

CAUTION

PWR

DCPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

Made in

USA

R5000-17HS

_________________
PRODUCT SERVICE

_________________
PRODUCT SERVICE

AC Power Supply (ACPS-17HS)
The ACPS-17HS includes a standard North American 3-pin
power cord which is UL (USA), CSA or CUL (Canada) listed
or approved. For installation in regions outside North
America, replace the power cord with a cord approved by ap-
propriate safety agencies. The cord must have a CEE-22 stan-
dard V female connector on one end and meet IEC 320-030
specifications. European power cords must be harmonized
and designated with a HAR marking on the outside of the
cord jacket to comply with the CENELEC Harmonized
Document HD-21.

WARNING

The default voltage setting on the ACPS-17HS is

115V AC. Before applying power, make sure the

voltage switch is set appropriately for the voltage

source in your region.

Replacing the Power Supply

To remove an ACPS-17HS or DCPS-17HS power supply
from the Radiance R5000 Central Service Platform, perform
the following steps.

IMPORTANT

Follow all precautions described in the box under

“Installing the Power Supply.”

1. Remove the power cord or wire leads from the power

supply.

2. Turn the thumb screws counterclockwise to loosen the

power supply from the platform.

3. Remove the power supply from the platform.
4. Install another power supply or a blank panel into the

empty slot. Refer to “Installing the Power Supply” for
installation instructions.