METRObility Optical Systems R200 User Manual

Page 7

Advertising
background image

Radiance R200 Premise Service Platform 7

4

Connect to the Network

To connect to the network, refer to the card’s installation and user guide
for information about the cable types and lengths supported.

Attach the Grounding Lug (R200-DC Only)

On the back panel, the R200-DC has a small hole where a grounding
lug must be installed. The hole is marked with the grounding symbol.
Use a 6-32 screw to fasten the lug (not provided) to the platform.
Connect the other end of the grounding lug wire to the grounding point
at your site.

Apply Power to the Platform

Power connections are located on the rear of the R200.

DC Power Supply Connections

IMPORTANT

• For installation in a restricted access location only.
• A readily accessible disconnect device must be incorporated in

the building installation wiring.

The R200-DC provides a three-position inverted header with screw
flanges (Phoenix Contact Combicon part number 1776511). For proper
connection to the power source, the header requires a plug connector
(Phoenix Contact Combicon part number 1777992 or equivalent).
NOTE: The plug connector is supplied with the R200. The input wire
leads are NOT supplied.

For DC connections, follow these guidelines:
IMPORTANT: Turn off the DC voltage source before beginning.

• Connect the wire leads from the voltage source to the appropriate

terminal on the plug connector and tighten the screws to secure the
wires in place.