6. symbols and definitions, Section 4 − installation, 1. specifications – Miller Electric 652 User Manual

Page 18

Advertising
background image

OM-228 470 Page 14

3-6. Symbols And Definitions

Some symbols are found only on CE products.

NOTE

A

Amperes

Amperage/Voltage

Control−Panel

Gas Tungsten Arc

Welding (GTAW)

Shielded Metal Arc

Welding (SMAW)

Temperature

Wire Feeder

Arc Force (DIG)

Gas Metal Arc

Welding (GMAW)

Output

Circuit Breaker

Remote

V

Volts

Positive High In-

ductance Weld

Output Terminal

Positive Low In-

ductance Weld

Output Terminal

Negative Weld

Output Terminal

Input

On

Off

Percent

Direct Current

U

0

Rated No Load

Voltage (Average)

U

1

Primary Voltage

U

2

Conventional Load

Voltage

Line Connection

I

1

Primary Current

I

2

Rated Welding

Current

X

Duty Cycle

Three-Phase

Transformer

Rectifier

IP

Degree Of

Protection

Three-Phase

S

1

KVA

Hz

Hertz

S

Suitable For Areas

Of Increased

Shock Hazard

Protective Earth

(Ground)

Submerged Arc

Welding (SAW)

The terms Sub Arc and Submerged Arc mean the same thing, and are used interchangeably

throughout this manual.

Note

SECTION 4 − INSTALLATION

4-1. Specifications

Model

IP

Rated

Welding

Amperage/

Voltage

Max

Amperes Input at Rated Load Output,

50 or 60 Hz, Three-Phase

Model

IP

Rating

Welding

Output

Voltage

Range DC

Max

OCV−DC

230

V

380

V

400

V

440

V

460

V

520

V

575

V

KVA

KW

650

21M

650 A @ 44

Volts DC,

50 − 815 A

In CC Mode

72 (70) VDC

In

CC Mode

126

3.8*

77

1.9*

73

1.8*

66

1.6*

63

1.9*

54

1.1*

50.4

1.4*

50

1.52*

34.8

0.76*

650

Amp

21M

Volts DC,

100% Duty

Cycle

10 − 65 V In

CV Mode

70 (66) VDC

In

CV Mode

3.8*

1.9*

1.8*

1.6*

1.9*

1.1*

1.4*

1.52*

0.76*

*While idling

( ) Indicates specification differences for CE models

Advertising