3. remote movement control connections, 4. installing gun onto mounting plate – Miller Electric MSC-2 User Manual

Page 12

Advertising
background image

OM-1096 Page 8

3-3.

Remote Movement Control Connections

ST-154 577

Slide movement can be controlled
by a remote device having a set of
normally-open contacts. Timing of
the contact closure is controlled by
the remote device.

1

MSC-2 Control

Open control door.

2

Strain Relief

3

Cord From Remote Device

Crimp proper terminals onto leads.

4

Terminal Strip 1T

Make connections, tighten strain
relief, and close and secure door.

A

B

C

D

E

F

G

H

J

K

F is circuit common

G to F = Up

H to F = Down

J to F = Right

K to F = Left

Tools Needed:

1

2

3

4

4

3-4.

Installing Gun Onto Mounting Plate

Ref. ST-154 578

A remote gun mount can be used to
install gun to slide.

1

Gun Mounting Plate

2

4-1/4 in. (108 mm)

3

4-1/4 in. (108 mm)

4

3/8–16 UNC Tapped Holes

Do not use screws longer than 1/2
in. (13 mm) to secure gun to plate.

1

2

3

4

Advertising