3. remote movement control connections, 4. installing gun onto mounting plate – Miller Electric MSC-2 User Manual
Page 12
OM-1096 Page 8
3-3.
Remote Movement Control Connections
ST-154 577
Slide movement can be controlled
by a remote device having a set of
normally-open contacts. Timing of
the contact closure is controlled by
the remote device.
1
MSC-2 Control
Open control door.
2
Strain Relief
3
Cord From Remote Device
Crimp proper terminals onto leads.
4
Terminal Strip 1T
Make connections, tighten strain
relief, and close and secure door.
A
B
C
D
E
F
G
H
J
K
F is circuit common
G to F = Up
H to F = Down
J to F = Right
K to F = Left
Tools Needed:
1
2
3
4
4
3-4.
Installing Gun Onto Mounting Plate
Ref. ST-154 578
A remote gun mount can be used to
install gun to slide.
1
Gun Mounting Plate
2
4-1/4 in. (108 mm)
3
4-1/4 in. (108 mm)
4
3/8–16 UNC Tapped Holes
Do not use screws longer than 1/2
in. (13 mm) to secure gun to plate.
1
2
3
4