Miller Electric MOG-350 User Manual

Page 16

Advertising
background image

OM-808 Page 12

3-3.

Weld Input/Output Cables For Resistance Grid (Dual Model Shown)

Y

Turn Off welding power
source, and disconnect in-
put power before making any
weld output connections.

1

Weld Input Cable

2

Work Cable

3

Weld Output Cable

If necessary, use Section 3-7 to
select proper cable size.

Use shortest cables possible.

Do not use damaged cables.

4

Terminal Lug

Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).

5

Common Work Connection

Connect work cable to common
work according to codes.

6

Insulated Electrode Holder

7

GTAW Torch

Install according to manufacturer’s
instructions.

8

Female Camlok Connector

Install onto weld input cable as
shown in Section 3-5.

9

Weld Input Receptacle

Connect cable to weld input recep-
tacle on rear panel of grid.

10 Male Camlok Connector

Install onto weld output cable as
shown in Section 3-6.

11 Electrode Receptacle

Connect electrode holder cable to
Electrode receptacle.

S-0793

Tools Needed:

Or

3

4

6

7

8

10

4

1

5

2

11

8

9

Advertising
This manual is related to the following products: