Remote, 7. weld cable size – Miller Electric MOG-350 User Manual

Page 19

Advertising
background image

OM-808 Page 15

3-7.

Weld Cable Size*

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Welding

Amperes

10 To 60%

Duty Cycle

60 Thru 100%

Duty Cycle

10 Thru 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

800

4/0

2-2/0

2-3/0

2-4/0

3-4/0

3-4/0

4-4/0

4-4/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007-D

3-8.

Optional Remote Receptacle Information And Connections

sb7.1 8/92* – Ref. S-0166-A / ST-080 370-A

1

Remote Receptacle

Single models have one Remote
receptacle RC3. Dual models have
two Remote receptacles RC3 and
RC4.

2

Keyway

3

Remote Grid Amperage
Control

4

Plug PLG1

5

Threaded Collar

To connect to this receptacle, align
keyway, insert plug, and tighten
threaded collar.

4

A

H

B

K

G

C

M

F

D

E

1

2

REMOTE

5

3

Advertising
This manual is related to the following products: