Finish to your taste, Installation components – Makita EST-48 User Manual

Page 17

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

Figure 47

FINISH TO YOUR TASTE

There are a wide variety of “finished looks” for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.

Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.

Outside Combustion Air Kits
(with duct)

81L87

FOAK

(without duct)

81L88

FOAK-LD

Combination
Offset/Return Elbow

63L35

FTF13-OR15

Firestop Spacer (30

°

)

63L37

F10FS30-2

Offset/ Return
Package (30

°

)

63L24

FTF13-ES30

INSTALLATION COMPONENTS

The following items are available for use in the
installation of this appliance.

The sum of all “R” values is:

.70 + .10 + .068 + .5825 = 1.4505

This would be an acceptable combination of
materials for the hearth extension since the
total calculated “R” value of all material used
exceed the required “R” value of 1.19.

WARNING: THE CRACK BETWEEN THE
FIREPLACE AND THE HEARTH EXTEN-
SION MUST BE SEALED WITH A NON-
COMBUSTIBLE MATERIAL.

WARNING: THE FIREPLACE MUST BE
RAISED IF THE HEIGHT OF THE HEARTH
EXTENSION EXCEEDS 8

¹⁄₂" ABOVE THE

BOTTOM OF THE FIREPLACE (

FIGURE

46 ).

Figure 46

8

¹⁄₂" Max.

Maximum Thickness of Hearth Extension
when EST-48 is on the Floor

Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 47.

Chase Termination
(Square)

63L54

FTF13-CT2

Stabilizer

63L27

FTF13-S4

Locking Band

63L60

FLB

4

³⁄₄"

3

¹⁄₄"

18" Min.

Distance to

Unprotected Side Wall

12" Min.

Distance to

Protected Side Wall

Fireplace

¹⁄₂"

Combustible

Materials Allowed

in Shaded Areas

15

°