Framing specifications – Makita EST-48 User Manual

Page 7

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

FRAMING SPECIFICATIONS

Figure 11

Figure 12

Framing Dimensions for Ceiling

Flue Type

A

B

FTF13 Vertical

19"

19"

(483 mm)

(483 mm)

FTF13

19"

29"

Offset 30

°

(483 mm)

(737 mm)

Figure 13

A

Outside Chase

G

C

J

Back Wall of Chase/Enclosure

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

FOAK

Combustion

Air Kit - Optional

Framing Dimensions for Roof

Pitch

C

D*

0/12

19"

19"

(483 mm)

(483 mm)

6/12

19"

22"

(483 mm)

(559 mm)

12/12

19"

27"

(483 mm)

(686 mm)

* Perpendicular to roof ridge

Figure 15

Figure 16

Figure 14

A

B

Ceiling Framing

C

D

Roof Framing

Corner Installation

K

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

FOAK Combustion

Air Kit - Optional

Framing Dimensions

Model EST-48

A

59

¹⁄₂"

1511 mm

B

53

³⁄₈"

1346 mm

C

44

⁄₂"

1130 mm

D

22

¹⁄₄"

565 mm

E

104"

2641 mm

F

52"

1321 mm

G

29

³⁄₄"

755 mm

J

31

³⁄₄"

806 mm

K

73

¹⁄₂"

1867 mm

Note: All framing dimensions calculated for 1/2"
dry wall at the fireplace face. If sheathing the
chase or finishing with other thickness materials,
calculations will need to be made. False header
should be constructed of 2 x material only.

A

G

Inside Chase

Back Wall of Chase/Enclosure

Including Finising Materials if any

Rough

Framing Face

(Unfinished

Shown)

FOAK

Combustion

Air Kit

A

B

Advertising