Specifications – MITSUBISHI ELECTRIC HS-S8300E(BRS) User Manual

Page 41

Advertising
background image

41

Tape Format:

VHS 1/2" width high-density video cassette tape.

Power Source:

AC100-230V, 50/60Hz.

Power Consumption:

Approx.20watts.

Television System:

625 lines, 50 field PAL-type colour system.

Heads-Video:

4 rotary single crystal heads.

Luminance Signal:

Frequency modulation recording.

Colour Signal:

Low frequency conversion, sub-carrier phase shift recording.

Audio Track:

1 track.

Tape Speed and Recording
Time (with E-180 cassette):

Mode

Time

Speed

Recording interval

Video signal

Audio signal

Tape drive

3H

3hrs

23.39mm/sec

20msec./Field

Continuous

Recordable

Continuous

L12H

15hrs

4.68mm/sec

100msec./Field

Time lapse

Recordable

Continuous (Slow)

L24H

27hrs

2.60mm/sec

180msec./Field

Time lapse

Recordable

Continuous (Slow)

48H

51hrs

340msec./Field

Time lapse

Not recorded

Time lapse

72H

75hrs

500msec./Field

Time lapse

Not recorded

Time lapse

96H

99hrs

660msec./Field

Time lapse

Not recorded

Time lapse

120H

123hrs

820msec./Field

Time lapse

Not recorded

Time lapse

168H

171hrs

1140msec./Field

Time lapse

Not recorded

Time lapse

240H

243hrs

1620msec./Field

Time lapse

Not recorded

Time lapse

360H

363hrs

2420msec./Field

Time lapse

Not recorded

Time lapse

480H

483hrs

3220msec./Field

Time lapse

Not recorded

Time lapse

720H

723hrs

4820msec./Field

Time lapse

Not recorded

Time lapse

960H

963hrs

6420msec./Field

Time lapse

Not recorded

Time lapse

0H

Time lapse

Not recorded

Time lapse

Fast Forward/Rewind Time:

Approx. 140sec. with E-180 cassette.

Audio/Control:

1 stationary head.

Erase:

1 full-track head.

Motors:

3 motors-drum/capstan direct drive system.

Video Input:

1.0Vp-p, 75ohms BNC plug. Y: 1.0 Vp-p, 75 ohms, C: 0.286 Vp-p, 75 ohms, S-connector.

Audio Input:

-8dBs, 50kohms, RCA plug.

Microphone Input:

-67dBs, 600ohms, mini mic jack.

Video Output:

1.0Vp-p, 75ohms BNC plug. Y: 1.0 Vp-p, 75 ohms, C: 0.286 Vp-p, 75 ohms, S-connector.

Audio Output:

-6dBs, 1kohms, RCA plug.

Horizontal Resolution:

More than 400 lines (S-VHS mode).
More than 240 lines (VHS mode).

Audio Frequency Response:

70Hz- 7kHz (3H mode).

Signal-to-Noise Ratio:

Video: better than 42dB.
Audio: better than 43dB.

Operating Temperature:

41°F-104°F (5°C to 40°C).

Relative Humidity:

Max.80(%)

Dimensions:

16.7(W)x12.4(D)x3.7(H)(in.).

(Jog dial included)

425(W)x315(D)x93(H)(mm).

Weight:

10 lbs (4.5kg.)

Alarm Recording Time:

Timed: 15 sec/30 sec/45 sec/1 min./2 min./5 min./10 min.
Manual 1: Until the alarm reset switch is switched on. Manual 2: Until the alarm set switch is switched off.

Display Format:

DISPLAY MODE 1: (Day)-(Month)-(Year) (Hour) : (Minute) : (Second) (Daylight saving time symbol or power failure symbol) (Alarm recording no.)
DISPLAY MODE 2: (Month)-(Day)-(Year) (Day of week) (Alarm recording no.),

(Hour) : (Minute) : (Second) (Daylight saving time symbol or power failure symbol) (Recording mode)

Display Position:

In any position.

Memory Program:

8 programs- daily start and stop time for one week.

Memory Backup:

Lasts 31days.

Elapsed Time Indicator:

The maximum of 89,999 hours.

CONNECTORS
SET Input:

Screw terminal for starting alarm recording.

RST Input:

Screw terminal for finishing alarm recording or for adjusting on-screen clock.

REC Input:

Screw terminal for starting/finishing recording, for series recording or for synchronous recording.

GND:

Screw terminal for ground.

ALM Output:

Screw terminal for output while alarm recording is under way.

CLK Output:

Screw terminal to command camera switching.

MODE Output:

Screw terminal for indication of VCR selected mode.

CALL Output:

Screw terminal for external warning device or for series recording.

REMOTE Jack:

Jack for connecting the remote control unit.

RS-232C interface:

D-SUB 9 pin connector.

Rating:
ALM/CALL/MODE

Active: “Low” level, max. Current 50mA (+5VDC)/10mA (+24VDC).
Non active: Open, max. Voltage +24V DC.

SET/RST/REC

Active: When terminals are short-circuited or “Low” level voltage applied.
Non active: Open, max. Voltage +17V DC.

CLK

Recording: A pulse of the frequency division ratio selected by REAR TERMINAL menu.

Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.

SPECIFICATIONS

Advertising