2. overload protection, 3. troubleshooting table – Miller Electric S-22P12 User Manual

Page 20

Advertising
background image

OM-181 931 Page 16

5-2.

Overload Protection

Ref. 800 586-B / Ref. 801 128-B

Y

Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.

1

Circuit Breaker CB1

2

Fuse F1

CB1 and F1 protect wire feeder
from overload. Correct problem and
reset CB1 or replace F1.

Close and latch door.

1

2

5-3.

Troubleshooting Table

Trouble

Remedy

Wire does not feed, unit completely inop-

Turn Power switch On.

erative.

Check fuse F1 and replace if necessary (see Section 5-2).

Check 14–pin plug PLG2 connections.

Check input power.

Wire does not feed.

Check circuit breaker CB1 and fuse F1. (see Section 5-2).

Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
Manual.

Have Factory Authorized Service Agent check drive motor and control board PC1.

Wire feeds erratically.

Readjust hub tension and drive roll pressure (see Section 3-8).

Use correct size drive roll (see Parts Listing).

Clean or replace dirty or worn drive roll (see Section 3-7).

Remove weld spatter around nozzle opening.

Replace contact tip or liner. See gun Owner’s Manual.

Have Factory Authorized Service Agent check drive motor and control board PC1.

Wire feeds when Jog switch is pressed
but not when gun trigger is pressed.

Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
Manual.

Wire feeds as soon as power is applied.

Check gun trigger. See gun Owner’s Manual.

Wire does not feed until trigger is
pressed but continues to feed after trig-
ger is released.

Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.

Gas valve rattles loudly and wire feeds
slowly or erratically.

Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.

Gas does not flow; wire feeds.

Check gas valve and flowmeter.

Advertising