This projector has 2 indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your
dealer.

POWER indicator

STATUS indicator

Normal condition

POWER

STATUS

CONDITION

NOTE

Steady

red

Off

Stand-by

Blinking

green

Lamp stand-by for power-off

The power cannot be turned on by pressing
the POWER button.

Steady

green

Blinking

green

Lamp stand-by for power-on

The power cannot be turned off by pressing
the POWER button.

Steady

green

The power is on. (Normal condition)

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

Steady

green

or

Steady

red

Blinking orange

Abnormal temperature
• The ventilation grilles are clogged with dust or dirt.
• The room temperature is high.

• Clean the ventilation grilles.
• Relocate the projector to a cooler place.

Steady

red

Blinking green

The protection circuit is working or the lamp is in an
abnormal condition.

• Wait until the STATUS indicator goes out,

then press the POWER button.

• If the above solution is not effective,

replace the lamp.

Steady

green

Blinking green/red

Lamp operation time warning. (Total lamp operation
time reached 3000 hours

*1

while the power was on.)

Replace the lamp.
Change with a new lamp if this problem
recurs.

Steady

red

Blinking red

Lamp operation time warning. (Total lamp operation
time reached 3000 hours

*1

while the power was off.)

Steady red

Lamp operation time warning. (Total lamp operation
time reached 4000 hours

*1*2

while the power was off.)

Blinking

green/red

Steady

or

Blinking

Abnormal.

Contact your dealer.

*1: Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be

shorted.

*2: When LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.