1.

SYMPTOM: THE SPA WILL NOT OPERATE

a. Check the power cord. The power cord must

be plugged into a grounded outlet (see PLUG-
GING IN THE RENEW 900 on page 10).

b. Check to see if the GFCI breaker is tripped, or

was not turned on. Reset the GFCI breaker.

2.

SYMPTOM: THE CIRCUIT BREAKER OR GFCI
BREAKER TRIPS WHILE THE SPA IS
OPERATING

a. Reset the circuit breaker. If the circuit breaker

trips again, contact a qualified electrician for
service.

3.

SYMPTOM: THE PUMP HUMS

a. The filter may be dirty or damaged. Remove

the filter housing from the spa jet unit and clean
or replace the filter.

b. The pump may have a foreign object stuck in

the impeller. Contact our customer service
department.

c. The pump may have a loose wire connection.

Contact our customer service department.

4.

SYMPTOM: THE PUMP HUMS BUT DOES NOT
ROTATE

a. The pump may be jammed. Contact our cus-

tomer service department.

5.

SYMPTOM: THE PUMP IS NOISY WHILE
OPERATING

a. There may be debris in the pump. Contact our

customer service department.

b. The pump may have a bad bearing. Contact

our customer service department.

6.

SYMPTOM: THE WATER DOES NOT HEAT

a. The heater is attached to the pump in the spa

jet unit. If the pump is operating, the water
should heat. Cover the RENEW 900 with the
spa cover. The spa cover must be tight. Set

the air control to low. The water will heat at a
rate of 1.7°F an hour. If you are using the spa
indoors, and the room temperature is main-
tained at 70°F, it will take approximately 20 to
28 hours for the water to reach the set temper-
ature.

b. If you are using the RENEW 900 outdoors, it

may take longer for the water to heat. See the
chart below for the approximate heating time.

Air Temperature

Heating Time

70°F +

20 to 28 hours

50°F–70°F

1 to 2 days

30°F–50°F

2 to 3 days

b.

If the water still has not heated after three
days, contact our customer service department.

7.

SYMPTOM: THE WATER PULSATES OR
THERE IS MINIMUM WATER FLOW

a. Adjust the water level. This usually occurs only

when the water level is low. Add water until the
filter and jets are covered.

b. This problem is caused by excess air in the

pump circulation system. Check to see if the
primer cap is fully tightened. Prime the pump
again and fully tighten the primer cap (see
PRIMING THE SPA JETUNITon page 10).

8.

SYMPTOM: THE SPA JET UNIT CAVITATES
DURING USE

a. Adjust the water level. This usually occurs only

when the water level is low. Add water until the
filter and jets are covered.

b. This problem is caused by excess air in the

pump circulation system. Check to see if the
primer cap is fully tightened. Prime the pump
again and fully tighten the primer cap (see
PRIMING THE SPA JETUNITon page 10).

9.

SYMPTOM: THE WATER IS NOT BEING
CLEANED BY THE FILTER

a. Check to see if the filter is in place. Clean the

filter if it is dirty.

TROUBLE-SHOOTING

Most problems can be solved by following the simple steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free
at 1-888-936-4266, Monday–Thursday, 8:00 am–6:30 pm; Friday, 8:00 am–6:00 pm EST (excluding holi-
days).

Advertising