IBM x Series 200 User Manual

Page 104

Advertising
background image

96

Hardware Maintenance Manual: xSeries 200

187

(VPD serial number not set.)

1.

Set serial number in Setup

2.

System Board

188

(Bad EEPROM CRC #2)

1.

Run Configuration/Setup

2.

System Board

189

(Three attempts were made to
access the server with invalid
passwords)

1.

Run Configuration/Setup, enter the administrator password

2.

System Board.

201

(Memory test error, see
"Memory Settings" on page
31.) If the server does not
have the latest level of BIOS
installed, update the BIOS to
the latest level and run the
diagnostic program again.

1.

Run memory diagnostics.

2.

DIMM

3.

System Board

229

(Cache error)

1.

Microprocessor

289

(DIMM has been disabled by
user or system, see "Memory
Settings" on page 31.)

1.

Run Configuration/Setup, if disabled by user

2.

Disabled DIMM, if not disabled by user.

301

(Keyboard or keyboard
controller error)

1.

Keyboard

2.

System Board

303

(Keyboard controller error)

1.

System Board

2.

Keyboard

602

(Invalid diskette boot record)

1.

Diskette

2.

Diskette Drive

3.

Cable

4.

System Board

604

(Diskette drive error)

1.

Run Configuration/Setup and Diagnostics

2.

Diskette Drive

3.

Drive Cable

4.

System Board

662

(Diskette drive configuration
error)

1.

Run Configuration/Setup and Diagnostics

2.

Diskette Drive

3.

Drive Cable

4.

System Board

Error Code/Symptom

FRU/Action

Advertising