IBM x Series 200 User Manual

Page 98

Advertising
background image

90

Hardware Maintenance Manual: xSeries 200

015-XXX-198

(USB device connected
during USB test)

1.

Remove USB devices from USB1 and USB2

2.

Re-run test

3.

System Board

020-XXX-000

(Failed PCI Interface test)

1.

System Board

030-XXX-000

(Failed Internal SCSI interface
test)

1.

System Board

030-XXX-00N

(Failed SCSI test on PCI slot
N. Check system error log
before replacing a FRU.)

1.

Adapter in Slot N

035-XXX-099

1.

No adapters were found.

2.

If adapter is installed re-check connection.

035-XXX-S99

(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)

1.

Adapter

2.

SCSI Backplane

3.

Cable

035-XXX-SNN

(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)

1.

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.

035-253-S99

(RAID adapter initialization
failure)

1.

ServeRAID Adapter in slot S is not configured properly.

Obtain the basic and

extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.

2.

Cable

3.

Adapter

075-XXX-000

(Failed Power Supply test)

1.

Power Supply

089-XXX-001

(Failed Microprocessor test)

1.

Microprocessor

180-XXX-003

(Failed System Board LED
test)

1.

System Board

201-XXX-0NN

(Failed Memory test, see
"Memory Settings" on page
31.) NN = DIMM location.

1.

DIMM Location J1-J4

2.

Memory card

Error Code/Symptom

FRU/Action

Advertising