INSTALLATIONS

PL-259 connector

q Slide the coupling ring over the coaxial cable. Strip

the cable jacket and pull back to reveal 10 mm of
braid.

• Soft solder the exposed braid and then pull out the jacket.

w Strip the cable as shown below. Soft solder the cen-

ter conductor the entire length of the exposed braid.

e Slide the connector body over the cable and sol-

der as shown below.

r Screw the coupling ring onto the connector body.

Solder

Solder

1–2 mm

10 mm

soft solder

10 mm

3

8

inches

Coupling

30 mm

10 mm (soft solder)

Mounting

Attach the AT-141 either horizontally or vertically with
one of the water drains facing downwards. After
mounting, remove the screw in the water drain.

Mounting on a Mast/Metal pole

Mounting on a flat surface

Nut

Spring
washer
Flat
washer(L)

Flat
washer(L)

Hex head
bolt

Drill a hole here
Diameter:7–8 mm;

9

32

5

16

inches

Weatherproof cap

Flat
washer(S)

Using self-tapping
screws

Using nuts and bolts

WARNING:

Mount the AT-141 securely with the

supplied nuts and bolts. Otherwise, vibrations and
shocks due to waves, etc. could loosen the antenna
tuner making if fall, causing personal injury.

Using U-bolts

U-bolt

U-bolt plate

Flat washer(L)

Spring washer

Nut

Mast/
Metal pole

Flat washer(S)

AT-141_0.qxd 05.12.1 11:06 Page 4

Advertising