3.2.4. Power Limit / Hazardous Energy Levels

Under normal or overload conditions, no output shall continuously provide 240 VA under
any conditions of load including output short circuit, per the requirement of UL 1950/CSA
950 / EN 60950/IEC 950.

3.2.5. Efficiency

3.2.5.1. General

The power supply required minimum is 70% efficient under “Full” load, 70% under
“typical” load, and 60% in a “light” load or idle condition. The efficiency of the power
supply should be tested at nominal input voltage of 115VAC input and/or 230VAC input,
under the load conditions defined in Table 7 and Table 8, and under the temperature and
operating conditions defined in Section 5. The loading condition for testing efficiency
shown in Table 8 represents a fully loaded system, a ~50% (typical) loaded system, and a
~20% (light) loaded system.

Table 7. Minimum Efficiency Vs Load

Loading

Full load

Typical load

Light load

Required Minimum Efficiency

70% 70%

60%

Recommended Minimum Efficiency

75% 80%

68%