6.3. Input Line Current Harmonic Content and Line Flicker

For sales in EU (European Union) or Japan the power supply shall meet the requirements of
EN61000-3-2 Class D and the Guidelines for the Suppression of Harmonics in Appliances
and General Use Equipment Class D for harmonic line current content at full rated power.
See Table 16 for the harmonic limits.

Table 16. Harmonic Limits, Class D Equipment

Per: EN 61000-3-2

Per: JEIDA MITI

Harmonic Order

n

Maximum permissible Harmonic

current at 230 VAC / 50 Hz in Amps

Maximum permissible Harmonic

current at 100VAC / 50 Hz in Amps

Odd harmonics

3

5

7

9

11

13

15

n

39

2.3

1.14

0.77

0.4

0.33

0.21

0.15 x (15/n)

5.29

2.622

1.771

0.92

0.759

0.483

0.345 x (15/n)

6.4. Magnetic Leakage Fields

A PFC choke magnetic leakage field should not cause any interference with a high-
resolution computer monitor placed next to or on top of the end-use chassis.